ACB A me MCCB
Hōʻuluʻulu manaʻo
Ua hoʻolālā ʻia ka GPU1/2/3 Series smart universal circuit breaker i nā huahana i hoʻomohala ʻia e mākou, helu ʻia ka volta o AC 50/60Hz, 480V(690V), helu ʻia i kēia manawa 200A ~ 6300A, hoʻohana nui ʻia no ka hāʻawi ʻana i ka mana a me nā kaapuni pale no ka hāʻawi ʻana i ka mana. pūnaewele, pale i ka mana lako a me ka uila nā mea pōʻino mai ka hewa o ka excessive overload, pōkole-kaapuni, honua hewa, etc.. He kiʻekiʻe precision koho koho a hoʻomaikaʻi i ka hilinaʻi o ka mana lako.Loaʻa i ka Breaker ka hana kaʻawale, e like me ke kūlana o GB 14048.2, IEC 60947-2
Nā hiʻohiʻona
1. Hoʻolālā paʻa
2. ʻAʻohe flashover mamao Palekana kiʻekiʻe
3. Hiki ke kiʻekiʻe o On-Off
4. Smart type over-current trip protection, with communication interface, Hiki ke ho'omalu 'ia e ka pu'upu'u kamepiula, ho'omaopopo i nā hana mamao.
5. Hōʻike i ka hana o ka ammeter, voltmeter
6. ʻAʻole pili ka piʻi a me lalo i ka hana huahana
Hoʻohālike
GPU3 | Mea hoʻoheheʻe kaapuni honua |
1600 | Kiʻi pale i kēia manawa |
4 | 3 ʻAʻole hōʻailona 3-phase 4 4-Mahele |
3M ano akamai hooponopono | Hoʻoponopono akamai ʻAno 2M: Hōʻike i ka paipu kikohoʻe, hoʻololi i ke pihi, ʻāpana 3 me ka hana pale hewa honua ʻAno 3M: Hōʻike LCD, hoʻoponopono pihi, ʻāpana 3 me ka hana pale hewa honua ʻAno 3H: hōʻike LCD, hoʻoponopono pihi a no ke kamaʻilio ʻana, 3 ʻāpana me hana hoomalu hewa honua. |
Ke ala kau ʻana | ʻAno huki ʻAno paʻa |
Hoʻohui ala | uea horizontal uea kupapau Pāpā-hope uea mua |
Koho koho | ʻO ka mea hoʻolele uila lalo Hoʻopili mīkini: 2 hoʻonohonoho a i ʻole 3 hoʻonohonoho hoʻopau i ka lever kūpaʻa i hoʻopaʻa ʻia 2 hoʻonohonoho i ka breaker horizontal a vertical i hoʻopaʻa ʻia e ke kaula kila Kūlana laka “Wehe” (laka kī) Huki-waho 3 kūlana kuapo Kūwaho hoʻohui N phase transformer |
In=630 | Heluhelu ʻia (A) |
Nānā:
1. ʻO ka mea hoʻoponopono akamai he ʻano M;Pākuʻi kōkua: 4 mau hui 'pili, ke ala hoʻohui ma ke ākea.
2. E ho'ākāka 'ia ke kumu kūʻai uila, ka mea hoʻokuʻu shunt, ka electromagnetic pili, ka mīkini hoʻokele kaʻa a me ka tripper ma lalo o ka voltage i ke kauoha.
Papa Koho Koho
ʻAno | Helu uila Ue(V) | Hoʻokaʻawale ʻia uila Ui(V) | Hoʻopaʻa ʻia ka hoʻoulu ʻana me ka uila Uimp (V) | Pākuʻi pale Inm o kēia manawa (A) | Kuhi ʻia i kēia manawa Inm (A) | Helu pae |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Hiki i ka haʻihaʻi pōkole | Kuhi ʻia ka manawa pōkole me ka Icw (kA)/1s o kēia manawa | Hana hana | |||||
Icu (kA) ka nui o ka hiki ana nahaha kaapuni pokole. | Ics (kA) i hiki | Ke ola mīkini (manawa) | Ke ola uila (manawa) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Hoʻoheheʻe Kaapuni Kaapuni
ʻO GPM11Z Smart Molded Case Circuit Breaker
Hōʻuluʻulu manaʻo o GPM11/GPM11Z
He kūpono ka GPM11 series molded case circuit breaker no AC 50/60Hz i helu ʻia i ka volta hana 400V/630V, helu ʻia i kēia manawa a hiki i 800A o ka mana hoʻolaha pūnaewele no ka hāʻawi ʻana i ka mana a me nā kaapuni pale, lako mana a me nā lako uila e kūʻē i ka overload, under-volt a me nā pōʻino kaapuni pōkole, hoʻomaikaʻi ia i ka hilinaʻi o ka lako mana ma lalo o nā kūlana hoʻohana maʻamau ʻaʻole i hoʻomaka pinepine ʻia e like me ka hoʻololi pinepine ʻana o ka laina a me ka moto.A me ka hana kaʻawale pū kekahi.E hui me ka maʻamau o GB/T 14048.2 a me IEC 60947-2.
Hoʻohālike
GPM11GPM11Z | Kaapuni Kaapuni i hooliliia |
100 | Kiʻi pale i kēia manawa |
H | Hiki i ka haʻihaʻi pōkole:N: ʻAno maʻamau S: ʻAno maʻamauH: ʻAno haki kiʻekiʻe |
P | Ke ala hana: Ka hana kaʻa: Protate lima hana: ZDirect hana (ʻaʻohe code) |
2 | ʻO ka hiʻohiʻona pale Koho: pale hoʻohele: ʻaʻohe code pale Motor: 2 |
4 | Māhele helu2 : ʻelua māhele3 : ʻekolu pae4 : ʻehā pae |
208 | ʻO ke ala huakaʻi a me nā code lako kūloko |
Ma=100 | Heluhelu ʻia (A) |
B | He 4 mau ʻano ʻokoʻa ʻē aʻe i kaha ʻia ʻo A, B, C, DA: ʻAʻole e hoʻokomo ka ʻāpana N i ka tripper o kēia manawa, a pili ʻo N i nā manawa a pau, ʻaʻole i hana ʻia me nā ʻano 3 ʻē aʻe. ʻAʻole i hoʻohana ʻia ka hana me nā ʻāpana ʻē aʻe 3.C: Hoʻokomo ʻia ka ʻāpana N i ka tripper o kēia manawa, a ua hana ʻia ka ʻāpana N me nā ʻāpana 3 ʻē aʻe.D: N phase i hoʻokomo i ka tripper o kēia manawa, a me ka N phase i pili mau, ʻAʻole i hoʻohana ʻia me nā ʻano 3 ʻē aʻe. |
Q | Ke ala uwea: Ke alo o ka uwila pā: QR ka hope o ka uwila pā: HʻO nā uwila ʻano hoʻopili: R |
'Ōlelo Aʻo: 1. ʻO ke ʻano o ka uwea ʻana: hope o ka uwila pā (400, 630's 4P me ka ʻole);uea ʻano plug-in (4P me ka ʻole)
2. Hoʻokomo ʻia nā lako kūloko ma ka ʻaoʻao hema o ka mea haʻihaʻi.
Papa koho ʻenehana no GPM11Z MCCB
ʻAno | Helu uila Ue(V) | Hoʻokaʻawale ʻia uila Ui(V) | Hoʻoholo ʻia kū i ka uila Uimp (V) | Pākuʻi pale Inm o kēia manawa (A) | Kuhi ʻia i kēia manawa Inm (A) | Helu pae | Hiki i ka haʻihaʻi pōkole | Kuhi ʻia ka manawa pōkole kū i kēia manawa Icw (kA) 1s | Hana hana | ||
Icu (kA) ka nui o ka hiki ana nahaha kaapuni pokole. | Ics (kA) i hiki | Ke ola mīkini (manawa) | Ola Uila (manawa) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Papa koho ʻenehana no GPM11 MCCB
ʻAno | Helu uila Ue | Ui uila hoʻokaʻawale i koho ʻia | Hoʻopaʻa ʻia ka manaʻo e kū i ka uila Uimp | Ua helu ʻia ka papa papa kiʻi iā Inm A | I kēia manawa ma (A) | Helu pae | Ua helu ʻia ke code hiki haʻi-pōkole kiʻekiʻe | Ua helu ʻia max pōkole - ka hiki ke wawahi kaapuni | Ics (kA) i hiki | ʻAno mea hele huakaʻi | Hana hana (manawa) | |
Ola | No-ola | |||||||||||
GPM11- 63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | ʻO ka electromagnetic wela | 3000 | 7000 |
3,4 | S | 25 | 18 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 3000 | 7000 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 1500 | 6500 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11- 225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 1500 | 6500 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11- 250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 1500 | 6500 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11- 400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 1000 | 4000 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11- 630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | ʻO ka electromagnetic wela | 1000 | 4000 | |||
3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | ||||||||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela | ||||||||
GPM11- 800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | ʻO ka electromagnetic wela | 1000 | 4000 | |||
3,4 | H | 65 | 50 | ʻO ka electromagnetic wela |