40.5kV SF6 Kaapuni Kaapuni GPFN Series
Hoʻohālike a me ke ʻano
E hoʻohana i nā Kūlana Kaiapuni
a.Ke kiʻekiʻe: ʻaʻole ʻoi aku ma mua o 1000m
b.ʻO ka mahana wela: -15 ℃ ~ + 40 ℃, ʻaʻole ʻoi aku ka mahana o kēlā me kēia lā ma mua o +35 ℃
c.ʻO ka haʻahaʻa o ke kaiapuni: ka awelika o ka haʻahaʻa pili i kēlā me kēia lā: ≤95% ka awelika o ka mahina: ≤90%
ʻO ke kaomi mahu awelika o kēlā me kēia lā: ≤2.2x10-3 MPa ʻO ke kaomi mahu awelika o kēlā me kēia mahina: ≤1.8x10-3MPa
d.Ka ikaika o ke ōlaʻi: ʻaʻole ʻoi aku ma mua o 8 degere
e.Kahi o ka hoʻohana ʻana: ʻAʻole haumia nui ka ea a puni e ka lepo, ka uahi, nā kinoea ʻino a/a i ʻole nā ea, nā mahu a i ʻole ka noe paʻakai.
'Ōlelo Aʻo: Inā ʻaʻole kūpono ka ʻenehana hoʻohana maoli i nā kūlana i luna, e ʻoluʻolu e kamaʻilio me kā mākou hui.
ʻĀpana ʻenehana
ʻAʻole. | Nā mea | Unite | ʻIkepili | |||
1 | Volta koho | kV | 40.5 | |||
2 | Ua helu pinepine ʻia | Hz | 50 | |||
3 | 1min mana alapine (frequency frequency) e pale i ka uila | Mawaena o na pou, I ka honua | kV | 95 | ||
Haʻihaʻi | 118 | |||||
ʻO ka uila uila kū i ka uila | Mawaena o na pou, I ka honua | 185 | ||||
Haʻihaʻi | 215 | |||||
4 | Kuhi ʻia i kēia manawa | A | 1250 1600 2000 2500 | |||
5 | Hoʻopaʻa ʻia ka manawa pōkole kū i kēia manawa (RMS) | kA | 25 | 31.5 | ||
6 | ʻO ke kiʻekiʻe i koho ʻia e kū i kēia manawa | 63 | 80 | |||
7 | ʻIke ʻia i kēia manawa hoʻokaʻawale pōkole (RMS) | 25 | 31.5 | |||
8 | Hoʻoholo ʻia i kēia manawa e hana ana i ka pōkole (waiwai kiʻekiʻe) | 63 | 80 | |||
9 | Ua helu ʻia ka lōʻihi o ka pōkole | s | 4 | |||
10 | Heluhelu ʻia o nā hana | O-0.3s-CO-180s-CO | ||||
11 | Hoʻoholo ʻia ma waho o ka pae honua ʻāhewa haki i kēia manawa | kA | 21.7 | 27.4 | ||
12 | Ho'āʻo ʻia ka hoʻololi ʻana i ka hoʻoili ʻana i kēia manawa | A | 50 | |||
13 | Hoʻokaʻawale ʻia ka panakō capacitor hoʻokahi/hoʻi i hope | 800/800 | ||||
14 | Ola mīkini | manawa | 10000 | |||
15 | ʻO ka wā hoʻomaha pōkole o kēia manawa | manawa | 30 | |||
16 | Kaapuni lua 1 min mana alapine (frequency frequency) pale i ka volta | 2000 | ||||
17 | Helu uila hana i koho ʻia | pani pani | V | DC110/220, AC220 | ||
wili wehe | V | DC110/220, AC220 | ||||
18 | Volta helu o ka mīkini mālama ikehu | W | DC110/220, AC220 | |||
19 | Ka mana helu ʻia o ka mīkini mālama ikehu | s | 250 | |||
20 | Ka manawa mālama ikehu (voltage helu) | s | ≤10 | |||
21 | Pumi helu ʻia o ke kinoea SF6 (ke kaomi ana ma 20°C) | Mpa | 0.350+0.02 | |||
22 | Pumi hoʻāla | Mpa | 0.29±0.01 | |||
23 | ʻO ke kaomi hana haʻahaʻa loa | Mpa | 0.28±0.01 | |||
24 | Ka helu leak makahiki | % | ≤0.5 | |||
25 | ʻAno kinoea kinoea | μL/L | ≤150 | |||
26 | ʻO ka hoʻoneʻe ʻana i ke kī ʻana | mm | ≥78 | |||
27 | Hoʻokaʻaʻike Spacing | mm | 50±1.5 | |||
28 | Ka manawa wehe | ms | 60~78 | |||
29 | Ka manawa pani | ms | 65~95 | |||
30 | ʻAʻole hoʻokahi manawa ka pani ʻana a me ka wehe ʻana | ≤5 | ||||
31 | Awelika ka māmā wehe (ma loko o 10ms ma hope o ka hapalua) | ms | 2.2~2.8 | |||
32 | ʻO ka wikiwiki pani maʻamau (ma loko o 10ms ma hope o ka hapalua ala) | ms | ≥1.5 | |||
33 | Main conductive loop pale | μΩ | ≤32(Kaʻa lima) | ≤20(ʻAno paʻa) |